SHE is so cool

Innovation

SHE is so cool

Flatpack2 SHE is the coolest conversion module ever - reducing wasted energy and heat dissipation to a minimum.
May 15, 2019

The Flatpack2 SHE Rectifier

The Flatpack2 SHE rectifier has taken conversion efficiency one step further, into the 98% range, thereby reducing waste by yet another 50% from the previous generation. And this with no compromise whatsoever when it comes to quality and reliability.

Proud heritage

The Flatpack2 HE and its high efficiency technology was a revolution in power conversion when it was first released in 2008. Featuring 96.5 % efficiency, the Flatpack2 HE has since defined the industry standard when it comes to quality and conversion efficiency. With some 2.7 million units in the field, the Flatpack2 HE has saved an estimated reduction in operating cost of some 835 million USD, and more than 5 million tons of CO2.

Flatpack2 SHE module

The SHE module is both cooler and greener than its predecessors – contributing to reduced cost of ownership, and a reduced environmental footprint in existing and new installations

Innovation at work

The Flatpack2 SHE is a natural evolution of the Flatpack2 HE, built on a technology that has been proven and tested over time. But it is also the result of innovative new solutions. In a joint development project with Infineon, a leading component supplier, a new type of GaN power transistors has been developed, tested and extensively verified. This CoolGaN™ technology helps increasing efficiency from high to super high, without driving cost through the roof. And, of course, without any compromise when it comes to the reliability or quality that Flatpack2 owners have become accustomed to.

50% reduction of power loss

Flatpack2 SHE is the coolest conversion module ever – reducing wasted energy and heat dissipation to a minimum. The difference between HE and SHE is illustrated below.

The savings effect and impact– in terms of reduced energy usage, environmental footprint and OPEX – depends on the number of modules replaced, their age and performance – and for new systems – the efficiency and reliability of alternative options.

Substantial savings potential

The following examples provide a fair representation of the savings potential:

Saving potential table

* Based on existing rectifiers with 92% efficiency **Source: Environmental Protection Agency (EPA) estimated one kilowatt-hour produces 1.52 pounds (0,689 kg) of carbon dioxide (excluding line-losses)

Erik Myhre, R&D Manager and head of the Flatpack2 SHE development team

We are confident that the Flatpack2 SHE has the most reliable and cost-effective module design in the market. It is based on the same proven concept that has made the Flatpack2 HE such a great success, but with efficiency stepped up through the introduction of new and innovative solutions

Erik Myhre, R&D Manager

An attractive option

This is a product that our customers will appreciate, says Joanne Conway, UK Sales Manager. Whether you are looking to upgrade older power systems, or invest in new ones, SHE power will be very attractive, particularly in countries where power prices are high. 15 years of backwards compatibility with Flatpack2 modules makes upgrading very easy – modules can be hot-swapped without interfering with system operation, says Joanne.

Eltek President Colin Howe can look back on a long career in the industry and in Eltek. He is both proud and pleased with the coming of SHE.

Wasting energy is costly. Not only for customers, but also for the planet. With SHE, we take one more step in the right direction, saving more power, by implementing a greener and more efficient technology.

Colin Howe, President and CEO

A cooler contribution

With efficiency in the “super high” region, the Flatpack2 SHE is the coolest conversion module ever – reducing wasted energy and heat by 50%. The savings effect and impact– in terms of reduced energy usage, environmental footprint and and OPEX – depends on the number of modules replaced, their age and performance – and for new systems – the efficiency and reliability of alternative options. – Aside from the attractive economics, we see our customers focus more and more on the environmental effects.

The sense of urgency is growing, and reliable, super-efficient power conversion is an important contribution when everything is added up. It is also a strong motivation for us at Eltek to continue pushing the barriers through innovation, says Colin Howe, President and CEO of Eltek.

The Flatpack2 SHE rectifier is available in a 3000 kW/48V version. A 2000 kW/48V will be available first quarter, 2018.

Download datasheet - Flatpack2 48V 3000W SHE

Download datasheet - Flatpack2 48V 2000W SHE

Download SHE brochure

close
1
Select efficiency
Select an Eltek module
or
Efficiency (%) of your existing system
2
Site load in kW
3
Local kWh price
kWh cost in your currency
result image
Your annual savings potential is
Energy:
0 kWh (1)
Energy Cost:
0 (2)
CO2:
0 tons (2)
4
How many sites do you have?
Your annual savings potential is
Energy:
0 kWh (1)
Energy Cost:
0 (2)
CO2:
0 tons (2)
  1. All figures is based on peak performance load
  2. Source Blueskymodel Environmental Protection Agency (EPA) estimated one kilowatt-hour produces 1.52 pounds (0,689 kg) of carbon dioxide (excluding line-losses).
SHE Calculator Check out your savings potential Calculate

This is Eltek!

This is Eltek! Eltek is a world leader in high-efficiency power electronics and energy conversion.
To the top